Potentia Plantae evacuationis Fan ab Hebei Ketong officina producta, maxime adhibita ad optimizing aeris circulationem in potentia plantarum officinarum, instrumentorum gurgustium, et facultates auxiliares, necnon emissionem summi temperaturae residua aeris, gasi pulvere oneratae, vel gasorum mechanicorum in processibus generationis potentiarum generatis, praestantibus evacuatione efficientiae et stabilis voluminis aeri potestate perficiendi ut residua et commoda operandi pro viribus exercendis.
Plerumque constitutum est in aere limbi coquentis machinae auxiliariae cubicula, portum exhauriunt turbinem generantis gurgustium, evacuationis exitum carbonum officinarum ratio tractandi, vel aeris permutationis sectionem stationum transformantium, authorem novum aerem in aream plantam deportandi, ac summos temperaturas aeris, carbonis pulveris gasi continentis, seu instrumenti caloris dissipationis, gasi circulationes in potentia productas, vaporem circulationem calculi, vaporem circulationem globorum, globorum globorum, globorum globorum, vaporum circulationes potentiarum, vaporum carbonum dissipationem et apparatum globum.
Hoc ventilabrum proprie convenit ad statio virtutis scelerisque, statio potentiae hydroelectricae (pro evacuatione officinae auxiliaris), facultates auxiliares Dicasteria apud plantas nuclei, novas conatus generationis energiae (sicut generatio virtutis solaris scelerisque), vel instrumenta electrica fabricandi et societates sustentandae.
Haec Potentia Planta Ventilatio Fan efficaciter moderari potest caeli ambitus in praecipuis locis potentiarum herbarum, plene occurrens evacuatione, caloris dissipatione, et pulvis remotio requisita potentiae generationis armorum et officinae, dum stricte obtemperans industriae nationalis potentiae securitatis signa et industriae plantae evacuationis et aeris qualitatem specificationum.
|
GY4-73 |
NO. |
R/Min |
Pa |
m³/H |
KW |
|
8D |
1450 |
2104~1400 |
16156~30993 |
18.5 |
|
|
9D |
1450 |
2668~1775 |
23003~44128 |
30/37 |
|
|
960 |
1163~775 |
15229~ 29216 |
11 |
||
|
10D |
1450 |
3301~2194 |
31554~60533 |
55 |
|
|
960 |
1437~958 |
20891~ 40077 |
15 /18.5 |
||
|
730 |
829~553 |
15886~3047 |
7.5 |
||
|
11D |
1450 |
4003~2659 |
41999~80570 |
75/90 |
|
|
960 |
1741~1160 |
27806~ 53343 |
22/30 |
||
|
730 |
1004~669 |
21144~40562 |
11 |
||
|
12D |
1450 |
4777~3171 |
54526~104600 |
132/160 |
|
|
960 |
2075~1381 |
36100~69253 |
37/45 |
||
|
730 |
1196~797 |
27451~52661 |
15 /18.5 |
||
|
14D |
1450 |
6541~ 4333 |
86586~166100 |
280/315 |
|
|
960 |
2831~ 1883 |
57326~109970 |
75/90 |
||
|
730 |
1630~1086 |
43591~83624 |
37/45 |
||
|
16D |
960 |
3709~2465 |
85571~164150 |
185 |
|
|
730 |
2133~1420 |
65069~124820 |
75 |
||
|
580 |
1343~893 |
51699~ 99178 |
45 |
||
|
18D |
960 |
4710~3126 |
121830~233730 |
280 |
|
|
730 |
2705~ 1800 |
92648~ 177730 |
132 |
||
|
580 |
1702~1133 |
73610~141210 |
75 |
||
|
20D |
960 |
5837~3870 |
167130~ 320160 |
||
|
730 |
3347~2225 |
127080~243800 |
220/250 |
||
|
580 |
2104~1400 |
100970~ 193700 |
110/132 |
||
|
22D |
960 |
6865~ 4864 |
23MMM~ 434000 |
650~850 |
|
|
730 |
3972~2815 |
177000~332000 |
310 / 370 |
||
|
580 |
2501~1775 |
141000~263000 |
165/180 |
||
|
480 |
1716~1216 |
116000~217000 |
140 |
||
|
25D |
730 |
5139~3648 |
260000~484000 |
570~ 700 |
|
|
580 |
3236~2295 |
206000~384000 |
280/350 |
||
|
480 |
2216~1579 |
171000~ 318000 |
165/210 |
||
|
28D |
730 |
6404~4541 |
365000~680000 |
1250 |
|
|
580 |
4040~2864 |
289000~540000 |
630 |
||
|
480 |
2775~ 1971 |
239000~446000 |
400 |
||
|
375 |
1697~ 1206 |
187000~352000 |
320 |
||
|
29.5D |
745 |
7218~5100 |
430000~810000 |
1250/630/1250 |
|
|
596 |
4609~ 3236 |
348000~648000 |
800/1000 |
|
Y5-47 |
NO. |
R/Min |
Pa |
m³/H |
KW |
|
4C |
3300 |
1922~1393 |
2751~5190 |
4 |
|
|
2900 |
1481~1079 |
2417~4561 |
3 |
||
|
5C |
2900 |
2324~1687 |
4723~8909 |
7.5 |
|
|
2620 |
1893~1373 |
4267~8048 |
5.5 |
||
|
6C |
2850 |
3364~ 2452 |
8020~15129 |
18.5 |
|
|
2620 |
2844~2069 |
7372~13908 |
15 |
||
|
8C |
2020 |
3001~2187 |
13474~ 25417 |
30 |
|
|
1860 |
2550~1853 |
12407~23404 |
22 |
||
|
9C |
1900 |
3364~ 2452 |
18045~34039 |
45 |
|
|
1800 |
3020~2197 |
17095~32247 |
37 |
||
|
12C |
1480 |
3628~2638 |
33318~62850 |
75~90 |
|
|
12.4C |
1480 |
3874~2824 |
36762~ 69347 |
110 |
|
Y5-48 |
NO. |
R/Min |
Pa |
m³/H |
KW |
|
4C |
3550 |
2221~1501 |
2932~5564 |
5.5 |
|
|
3150 |
1746~1180 |
2602~4937 |
4 |
||
|
2800 |
1377~932 |
2313~4388 |
3 |
||
|
2500 |
1097~742 |
2065~3918 |
2.2 |
||
|
5C |
3150 |
2819~1913 |
5304~9851 |
11 |
|
|
2800 |
2223~1509 |
4715~8757 |
7.5 |
||
|
2500 |
1769~1202 |
4210~7818 |
5.5 |
||
|
2240 |
1419~964 |
3772~7005 |
4 |
||
|
6.3C |
2800 |
3545~2403 |
9432~ 17516 |
22 |
|
|
2500 |
2819~1913 |
8421~15639 |
15 |
||
|
2240 |
2259~1533 |
7546~ 14013 |
11 |
||
|
2000 |
1798~1221 |
6737~ 12511 |
7.5 |
||
|
8C |
2000 |
3323~2253 |
13794~ 25619 |
30 |
|
|
1800 |
2686~1823 |
12415~23057 |
22 |
||
|
1600 |
2118~1438 |
11035~ 20495 |
15 |
||
|
1400 |
1619~1100 |
9656~17933 |
11 |
||
|
10C |
1800 |
4483~2958 |
22250~44634 |
75 |
|
|
1600 |
3531~2332 |
19778~ 39674 |
55 |
||
|
1400 |
2696~1782 |
17305~34715 |
37 |
||
|
1250 |
2145~1419 |
15451~30995 |
22 |
||
|
12.5 gradus Celsius |
1400 |
4234~2794 |
33800~ 67803 |
110 |
|
|
1250 |
3365~2223 |
30179~60538 |
75 |
||
|
1120 |
2696~1782 |
27040~54242 |
55 |
||
|
1000 |
2145~1419 |
24143~ 48431 |
37 |
|
GY6-51 |
NO. |
R/Min |
Pa |
m³/H |
KW |
|
8D |
1450 |
2745~1859 |
10000~26400 |
15~22 |
|
|
9D |
1450 |
3474~ 2353 |
15700~ 37500 |
30/45 |
|
|
10D |
1450 |
4289~2905 |
21500~51500 |
45~75 |
|
|
11D |
1450 |
5190~3515 |
28600~68500 |
75~ 110 |
|
|
960 |
2275~1541 |
18900~45400 |
22/30 |
||
|
12D |
1450 |
6176~ 4183 |
37100~89000 |
110~160 |
|
|
960 |
2707~1834 |
24600~59000 |
37~55 |
||
|
13D |
1450 |
7248~ 4909 |
47200~ 113000 |
185~250 |
|
|
960 |
3177~ 2152 |
31200~ 74900 |
55/75 |
||
|
14D |
1450 |
8406~ 5694 |
58900~141000 |
250~ 355 |
|
|
960 |
3685~2496 |
39000~93400 |
75~ 110 |
||
|
15D |
1450 |
9650~6537 |
72400~172000 |
355~500 |
|
|
960 |
4230~2865 |
48100~115000 |
110~160 |
||
|
730 |
2446~1657 |
36600~87400 |
45~75 |
||
|
16D |
1450 |
10980~ 7437 |
88100~211000 |
500~710 |
|
|
960 |
4813~3260 |
58300~140000 |
160~200 |
||
|
730 |
2783~1885 |
44300~106000 |
75/90 |
||
|
17D |
960 |
5433~3680 |
69900~16800 |
200~ 280 |
|
|
730 |
3142~2128 |
53200~ 128000 |
90~132 |
||
|
18D |
960 |
6091~4126 |
8MMM~19000 |
250~ 355 |
|
|
730 |
3522~2386 |
63100~151000 |
110~160 |
||
|
19D |
960 |
6787~4597 |
97600~234000 |
315~500 |
|
|
730 |
3924~2658 |
74200~ 178000 |
160~200 |
||
|
20D |
960 |
7520~5094 |
114000~273000 |
450~630 |
|
|
730 |
4348~ 2946 |
86700~ 208000 |
185~280 |
||
|
21D |
960 |
8290~5616 |
132000~ 316000 |
560~800 |
|
|
730 |
4794~ 3247 |
100000~240000 |
280/355 |
||
|
580 |
3026~2050 |
79500~191000 |
220 |
||
|
22D |
960 |
9099~6164 |
152000~363000 |
710 ~ 1000 |
|
|
730 |
5261~3564 |
116000~276000 |
315~ 450 |
||
|
580 |
3321~2250 |
92200~ 219000 |
220 |
||
|
23.5D |
960 |
10380~ 7033 |
185000~443000 |
1000~1400 |
|
|
730 |
6003~4066 |
140000 ~ 336000 |
400~630 |
||
|
580 |
3789~2567 |
112000~ 267000 |
220~315 |
||
|
25D |
730 |
6794~ 4603 |
169000~406000 |
630~800 |
|
|
580 |
4289~2905 |
134000~323000 |
280~ 400 |
||
|
26.5D |
730 |
7633~5172 |
201000~483000 |
800~1120 |
|
|
580 |
4818~ 3265 |
160000~385000 |
400~560 |
||
|
480 |
3300~2236 |
132000~319000 |
220~315 |
||
|
28D |
730 |
8522~5774 |
237000~569000 |
1000~1400 |
|
|
580 |
5280~3645 |
189000~454000 |
560~710 |
||
|
480 |
3685~2496 |
156000~376000 |
315 / 400 |
||
|
29.5D |
730 |
9460~6410 |
278000~667000 |
1250~2000 |
|
|
580 |
5972~4046 |
221000~530000 |
710 ~ 1000 |
||
|
480 |
4090~2771 |
185000~439000 |
400~560 |
1.Advanced Impeller et Airflow Design: Impeller consilium pendet pro fan perficiendi. Multa exempla scapulis retrorsum-curvis utuntur ad stabilitatem meliorem et lapsum deminuendi. Studia optimizationem aerodynamicam ostendunt, utpote addito corpore centrali ad impellentem diverticulum, totalem pressionem efficientiam per 5-10% emendare posse, efficaciter optimizing aeris fluxum seminis.
2. Optimized Habitationi et Inletus Geometria: Habitatio helica specialiter destinatur ad pressionem conversionem efficientem. Praecipuus curatur ad structuram diverticulum et "linguam". Angulus linguae initialis aptans efficientiam 2-3% emendare potest, dum minuens separationem ad humiles rates fluit, ita stabilis operans range dilatans.
3.Durable Drive and supporting System: Haec potentia plantae ventilationis ventilatio ad fidem destinatur, adhibita inculcationibus et efficacia sigillis auctis ad prohibendos ultrices ducatus. Praeterea lubricatio cum machinis oleum (exampla, L-AN46) efficit stabilitatem etiam sub continua operatione.
4.Energy Efficens sub diversis condicionibus operans: Potentia fans plantarum ad operandum sub alta pressura, altae condiciones fluunt, sed eorum industria efficientiae scutorum universaliter applicabiles sunt. Exempli gratia, etiam summus pressurae commercialis ante-curvae fans centrifugae operandum est in summa sua industria efficientiae vagandi ut nimiam vim damni et soni gradus vitet.










Oratio
Changboluo Villa, Siying Urbs, Botou urbs, Cangzhou, Hebei provincia, China
Tel
Percontatione de ventilabro centrifuga, ventilabro flabello inductus captura ventilabrum vel album pretiosum, electronicam tuam nobis relinque, et intra 24 horas erimus continuaturi.
